Reverse Osmosis Systems
EXPLANATION
STANDARD FEATURES
- Membrane covers FRP
 - TFC Spiral winding membranes 8 \ ”diameter
 - AISI304 or AISI316 quality stainless steel vertical centrifugal high pressure pump
 - ST-37 Epoxy painted carbon steel or AISI304 Stainless steel chassis
 - 5 Micron precision cartridge filter
 - Low pressure line U -PVC PN16
 - High pressure line AISI304 Stainless steel
 - Butterfly valve with electric actuator on inlet
 - Pressure regulating globe valves in pump outlet and waste water line
 - Low and high pressure switch
 - Product water and waste water flowmeters
 - Glycerine manometers
 - Product water conductivity indicator (0-2000µS /cm)
 - Product water pH meter (optional)
 - Autoflush, automatic rinsing and chemical flushing System
 - On-Off switch
 - PLC and operator panel
 - 380 V / 50Hz / 3ph
 - IP56 control panel
 
Recommended Input Water Limits
 Input water TDS: 0 - 2,000 ppm
 Operating pressure: 10 to 15 bar 
Inlet water pressure: 2 to 5 bar 
If hardness is more than 3 French, ASC dosage required
 pH range: 6 - 8 
Silica (SiO2) Tolerance: 25 ppm max. @ 60% efficiency
 Max. Inlet water temperature = 30º C Max.
Max Iron (Fe) tolerance: 0.05 ppm, 0.2 ppm 
Hydrogen Sulfide should not exist if ASC is dosed.
There should be no turbidity 