Reverse Osmosis Systems

CATEGORIES


EXPLANATION

STANDARD FEATURES

  • Membrane covers FRP
  • TFC Spiral winding membranes 8 \ ”diameter
  • AISI304 or AISI316 quality stainless steel vertical centrifugal high pressure pump
  • ST-37 Epoxy painted carbon steel or AISI304 Stainless steel chassis
  • 5 Micron precision cartridge filter
  • Low pressure line U -PVC PN16
  • High pressure line AISI304 Stainless steel
  • Butterfly valve with electric actuator on inlet
  • Pressure regulating globe valves in pump outlet and waste water line
  • Low and high pressure switch
  • Product water and waste water flowmeters
  • Glycerine manometers
  • Product water conductivity indicator (0-2000µS /cm)
  • Product water pH meter (optional)
  • Autoflush, automatic rinsing and chemical flushing System
  • On-Off switch
  • PLC and operator panel
  • 380 V / 50Hz / 3ph
  • IP56 control panel

Recommended Input Water Limits

Input water TDS: 0 - 2,000 ppm
Operating pressure: 10 to 15 bar
Inlet water pressure: 2 to 5 bar
If hardness is more than 3 French, ASC dosage required
pH range: 6 - 8
Silica (SiO2) Tolerance: 25 ppm max. @ 60% efficiency
Max. Inlet water temperature = 30º C Max.
Max Iron (Fe) tolerance: 0.05 ppm, 0.2 ppm
Hydrogen Sulfide should not exist if ASC is dosed.
There should be no turbidity